Marking and Labeling

excam-ipq1656-weblogo.png

Model Key: T08-VA2.3.K3.BOR2-N.H-***.A-T

PN: 22070521


Certification T08-Series


Ex-Marking

Model Key: T08-VA2.3.K3.BOR2-N.H-***.A-T
PN: 22070521
Serial No.: from PT0805756*
Prod. Year: from 2024
Power Supply: PoE C3, Typ.: 5.1W, Max.: 8.2W
Temp. Range: -20°C < Tamb < +60°C
Prot. Degree: IP68

TÜV 18 ATEX 8218X
Ex II 2G Ex db IIC T6 Gb
Ex II 2D Ex tb IIIC T80°C Db

No.RU.C-DE.HA65.B.01652/22
1Ex db IIC T6 Gb
Ex tb IIIC T80°C Db

IECEx TUR18.0023X
Ex db IIC T6 Gb
Ex tb IIIC T80°C Db

WARNING:
DO NOT OPEN IN POTENTIALLY EXPLOSIVE ATMOSPHERES
Observe the safety instructions in the installation guide!

Not your language? Translate

To top

* for older serial numbers please contact supportsamcon.eu


Special conditions for safe use

  • The device must not be used for applications in the mining industry (ATEX group I), nor in other hazardous areas with potentially "high" risk of damage caused by mechanical stresses (ATEX group II)!
  • No holes, whether blind or clear, may be drilled in the ExCam enclosure other than already provided by the manufacturer.
  • The requirements of EN/IEC 60079-14 must be applied.
  • All used cable glands and plugs have to be certified.
  • Attention: The pre-installed Ex-e terminal box has a different permissible ambient temperature range (-60°C ... +55°C) than the camera. The terminal box doesn't have MASC approval.
  • Due to the high weight of the camera, we recommend the use of a mechanical fall arrester (e.g. safety wire) in addition to the standard wall mount or ceiling mount bracket.

Datasheets, User Manual, Drawings, Certification, ... can be found on the product page


Manufacturer data / certificates

SAMCON GmbH
Schillerstr. 17
35102 Lohra
Germany

Manufacturer certificates