Safety instructions

Attention

  • Absolutely observe the installation's safety directions of the T08 ExCam series!
  • Observe the instructions stated on the type plate!
  • The camera is not suitable for use in zone 0 and 20!
  • Temperature class and explosion group must be absolutely adhered to!
  • The specified temperatures have to be observed!
  • The customer is not allowed to make any alterations of the camera.
  • The camera must be operated in a proper and sound condition and only in the way intended.
  • Repairs may only be carried out by using original parts from the manufacturer. Repairs which affect explosion protection may only be carried out in accordance with the nationally applied regulations and exclusively by the manufacturer.
  • When installing the ExCam adhere to the requirements of the EN/IEC 60079-14.
  • The ExCam devices with model key T08-VA4.1K.PS1 (optical thermoplastic) must generally not be used for applications in the mining industry (ATEX group I), nor in other hazardous areas with potentially "high" risk of damage caused by mechanical stresses (ATEX group II)!
  • Risk of electrostatic charging! Clean only carefully with a soft, damp cloth.
  • Be careful not to damage the dome’s UV resistant coating. Avoid scratches.

Warnings

WARNING:
DO NOT OPEN IN POTENTIALLY EXPLOSIVE ATMOSPHERES
Observe the safety instructions in the installation guide!
--------------------------------------------------------------------------------------------------------
ВНИМАНИЕ:
НЕ ОТКРЫВАТЬ в потенциально взрывоопасных средах
Соблюдайте инструкции по технике безопасности в руководстве по установке!
---------------------------------------------------------------------------------------------------------
AVERTISSEMENT:
NE PAS OUVRIR EN ATMOSPHÈRES EXPLOSIBLES
Respectez les consignes de sécurité dans le guide d'installation!
---------------------------------------------------------------------------------------------------------
AVISO:
NÃO ABRIR DENTRO DE UMA ÁREA COM PERIGO DE EXPLOSÃO
Observar as instruções de segurança nas instruções de instalação!

Technical data

Explosion protection

 

Identification marks acc. to
Directive 2014/34/EU

Ex II 2G (zone 1 and 2)

Ex II 2D (zone 21 and 22)
Explosion protection (gas)Ex db IIC T6 Gb
Explosion protection (dust)Ex tb IIIC T80°C Db
Protection levelIP 66/68 (IEC /EN 60529)
Transport/ storage temperature-40°C…+65°C (non-condensing)
Ambient temperature (EX)-50°C...+60°C
Named testing laboratoryTÜV Rheinland (number 0035)
EU type approval certificateTÜV 18 ATEX 8218X (2018)
IECEx Cert. of ConformityTUR 18.0023X (2018)
INMETRO-CertificateTÜV 23.0363X (2023)
EAC-Ex TUR ReportTC RU C-DE.HA65.B.01652/22

Model key

Ex product name

Model variants

Artikelno.

1)

2)

Type

 

3)

Housing-(combination)

4)

Temp.-range

5)

Cable length [m] cable type

6)

Termination

Link to digital type plate

ExCam
IPP3827

T08-

VA4.1K.PS1-

LL.H-

000.X-

X

T08-VA4.1K.PS1-LL.H-005.N-P22070492
T08-VA4.1K.PS1-LL.H-005.N-T22070493
T08-VA4.1K.PS1-LL.H-005.A-P22070494
T08-VA4.1K.PS1-LL.H-005.A-T22070495

 

Description:

  1. ExCam IPP3827 = Funktional camera description of the ExCam Series (technical data/ specification of the individual camera module)
  2. T08 = SAMCON Production- type 08
  3. VA4.1K.PS1 = T07 Ex-d housing (stainless steel 1.4404) with large diameter ØVA4=216mm) VA4.1K.PS1 = T07 VA4.1 housing with short body lenght (LR = 145mm)
    VA4.1K.PS1 = No cable- gland flange
    VA4.1K.PS1 = Thermoplastic Dome
  4. LL.H = LowLow temperatures (Tamb > -50°C)
    LL.H = High temperatures (Tamb < +60°C)
  5. 000.X = No connection line delivered
    005.X = Length of connection cable in meters at delivery; 5m is standard; max. cable length is: 005…100 [m]
    005.N = Non armoured cable
    005.A = Armoured cable
  6. X = flipConnect for easy electrical connection
    P = Plug- termination (Standard); CAT6, RJ-45 network plug (heavy duty), AWG 26-22; Pin assignment acc. specification EIA/TIA-568B
    T = Terminal Box - termination (Optional); 4 x PoE Mode A connection (Camera PoE)
    (see electrical connection)

Electrical parameters

Voltage supply: PoE, IEEE 802.3at type2 class 4
Reference voltage: +48 V DC (44...54 V DC)
Maximum power consumption: 18 W
Typical power consumption: 12 W

Connection cables

Appropriate cables & cable glands:

for this watch the following video-tutorial or the informations on the cable-page.

Attention!

  • Cables and wires must comply with the requirements of the IEC 60079-0/1/7 & 14.
  • The supply line must have a sufficient cross-section. The cable protection must comply with national and international regulations.

To top

Video-technical characteristics

Other technical data

Permissible ambient temperature: -50°C ... +60°C
Protection class as per EN 60529/IEC 529: IP66/68 (test conditions 24h/3m water column at 5°C)
Housing material: Stainless steel mat. no.: 1.4404
Weight: ca. 15kg
Dimensions: D216mm x 235,89 mm

Mounting

  • Check device for transport damage on housing and cable.
  • Carefully choose installation site (lightning conditions, object distance,...)
  • Optional mounting accessories for easy fixation on Pole, Wall (hanging) or Ceiling/ Wall vertically.
  • Depending on classification of hazard areas, it is imperative to obtain a work approval first!
    When you open the pressure-resistant enclosure under voltage, it is absolutely necessary to prevent potentially explosive atmosphere!
  • Observe national safety, installation and accident prevention regulations (e.g. DIN EN 60079-14), safety instructions in the EX installation instructions and ATEX/IECEx regulations!
  • Observe national and local regulations for mounting heavy loads. If in doubt, take appropriate safety measures.

Attachment with the Wall mount Bracket

To top

Electrical Connection

  • May only be carried out by qualified personnel!
  • Ground the housing via PA-connection!
  • Cabels  have to be layed protected, observe bending radius!
  • Electrical work inside the pressure resistant enclosure by the user are not authorized!

To top

Potential Equilization

ExCam-IPP3807---T08-VA4.1K.PS1-x.x-005.N-P_rev.00_Pfeil.png

Cross Section > 4mm² / Torque 1,2Nm

To top

Connection work via flipConnect

Attention

  • The device is connected exclusively via flipConnect.

The procedures are showen in the following video tutorial
“Plug & Play Cable Connection via flipConnect”

 

 

To top

Appropriate cables and cable entries

for this watch the following video-tutorial or the informations on the cable-page.

Attention

  • Cables and wires must comply with the requirements of the IEC 60079-0/1/7 & 14.
  • The supply line must have a sufficient cross-section. The cable protection must comply with national and international regulations.

    Rubber ring sealing screw connections

    Make sure that the gland encloses the upper part of the plug and does not press on it.

    Barrier cable glands

    In combination with barrier cable glands do not use the included plug. Remove the outer jacket of the network cable and terminate its end with a suitable crimp connector. Pay attention to correct handling and follow the instructions in the respective installation instructions.

    To top

    Plug Assignment

    Plug assignment RJ45 plug acc. to EIA/TIA 568B

    Connection work with plug

     

     

    Attention!

    • Use appropriate RJ45 plugs! Check the cable shielding, cross-section and the outside diameter!
    • It is imperative to ensure a correct routing of the individual wires acc. to EIA/TIA-568B.
    • Finally, check your network installation with a Class-D Link test.

    To top

    Tests prior to switching on voltage

    Attention!

    • Prior to starting the device, perform all tests as indicated by the national regulations. Furthermore, check the correct function and installation of the device in accordance with this User Manual and other applicable regulations.
    • Incorrect installation or operation of the camera may lead to a loss of warranty!
    • Do not switch on the camera at temperatures below 0°C!

    Working inside the camera housing (Ex-d)

    Reasons for opening the housing:

    • Adjust the camera position
    • Exchange of the SD memory card
    • Hardware-reset

    Important!

    • Depending on classification of hazard areas, it is imperative to obtain a work approval first!
    • Prevent explosive atmosphere!
    • Do not damage the thread surface of the flame-proof gap and the housing seals!

    Opening the pressure-resistant housing

    Remove or loosen the bolted connections of the camera housing flange and body.

    Carefully pull out the dome flange strictly vertically/perpendicularly. Because of negative pressure, it may be difficult to remove the flange. The cylindrical clearance fit (H8f7 - DIN ISO 286) of the camera body and flange may not be tilted! Risk of damage to the flame-proof gap (DIN EN 60079-1:2012)!

    ExCam-XF-P3807_Demontage-Kuppelflansch_rev.png

    Attention!
    Use particular care when dealing with installed components (camera module, optics, temperature control, electronics, etc.) which are fixated above the mounting adapter on the cable and supply flange (cable gland). Risk of damage!
    When removing the flange, ensure that the Gylon flat gasket (Style 3504, blue) does not get damaged or dirty!

    Adjusting the camera position

    Kameraposition_XFP3808.JPG

    The camera position could be adjusted manually in the following ways:
    Manual turning +5°, manual panning +180°, manual tilting 0° bis 50°

    Removing / inserting a SD memory card

    Reset2.JPG

    The ExCam IPP3827 has a slot for a micro SDHC memory card (card not included). Saved video files can be played and deleted via the web interface. They are also available in a download list. Moreover, the videos available in the memory card can also be accessed via FTP server in the network.If the memory card has to be replaced by the user, it should be, as far as possible, empty and pre-formatted with an ext4 or vFAT file system.

    When touching electrical components, observe potential equalization (grounding of the body): carry electrostatic-discharge clothes, a PE wristband etc.!

    Hardware Reset

    To set all the parameters of the ExCam IPP3827 (including the IP address) to default values, you should run a hardware reset. The parameters can be reset via the web interface or manually. If the camera placed in the network can no longer be reached or its state is uncontrollable, the reset should be per-
    formed manually. To do so, proceed as follows:

    1. Disconnect the camera installation module (Axis P3827) from the power supply.
    2. Press and hold the control button (see the illustration below) and, at the same time, connect the system to the voltage supply (PoE).
    3. Hold the control button pressed for about 30 seconds.
    4. Release the control button. After about a minute, the AXIS P3827 will return to factory defaults. If there is a DHCP server in the network, the IP address will be the following: 192.168.0.90 (subnet masking 255.255.255.0).
    5. IP address and password can be redefined. If the hardware reset is not satisfactory or the network camera shows serious conflicts or does not work as usual (errors in the browser visualisation, frozen images, control commands no longer processed, slowing down of the system, etc.), it may be necessary to re-install the current firm-ware, or to install an update.

    Closing of the pressure-resistant housing

    For closing the housing, proceed in reverse order as when opening. Use exclusively original screws included in the supply. The cable and power-supply flange (K1) is fixed by 8 cylinder-head screws M4*0.7 (ISO metric right-turning) with 12 mm thread length (DIN 912/ ISO 4762, grade 6g). Materials of bolted connections are identical to the pressure-resistant stainless steel housing (standard material no. 1.4404 AISI316L). Check whether the threaded holes are undamaged and clean. Before closing, it is also absolutely imperative to check the flame-proof gap (circular cylindrical fit).

    Attention!
    If any mechanical damages occurred to the fitting gap, it is no longer allowed to use the housing!

    Attention!
    Do not lock-in any foreign objects in the housing.

    Dismantled screw locks (spring washers DIN 127A) must be used again. The GYLON® gasket must be used in undamaged condition, according to the flange hole pattern, and placed between the flange and the hull. The lateral position of the flat surface / contact surface is arbitrary. If, when closing the housing, you see that the surface of the fitting gap is dirty or insufficiently lubricated, clean it with a clean cloth and de-grease it with a suitable cleaning agent. Then re-grease it with lubricant suitable for this specific application (e.g., Molykote® P-40 gel for standard applications or special grease OKS 403 in the event of heavy seawater influence).

    Cylinder-head bolts for explosion-proof connection of the camera body with the flange component must always be tightened at a 3 Nm torque - crosswise and evenly! Use Loctite.

    Attention

    • Insert the flange to reach the end position, in order to ensure ignition protection and the protection level (IP) of the housing.
    • The M6 screwed connections of the VA4.x flange and body components must always be tightened crosswise with a torque of 9.0 Nm! If the bolted connections are tightened too strongly, it can cause damages to the device!
    • Do not to damage the surface of the drill hole and the shaft (fitting) of the flame-proof gap.
    • Ensure that you do not damage the housing seals. Keep them clean.
    • If the fitting gap is mechanically damaged, it is no longer allowed to use the housing!
    • If the dome is damaged, it must no longer be used!
    • Ensure that no foreign objects are entrapped in the housing.

      Network Access, Installation and Comissioning

      Initial start-up

      https://help.axis.com/en-us/axis-p3827-pve

      https://help.axis.com/api/download/um_p3827pve_panoramic_camera_t10182890_en_2308.pdf

      Applicable net frequency: 50Hz or 60Hz
      Carry out other net frequency: menu System Options > Advanced > Plain Config

      User: root
      Password: root

      To top

      Browser support

      A list of the currently supported web browsers, operating systems, required add-ons, etc. can be viewed at:
      https://help.axis.com/access-your-device
      https://www.axis.com/support

      To top

      Allocating IP Adress

      The ExCam IPP3827 is intended for use in an Ethernet network and requires an IP address to access and control it. In the most today's networks, a DHCP server is integrated. This server automatically assigns an IP address. If there is no DHCP server available in the network, the IP default address of ExCam IPP3827 is "192.168.0.90" (subnet masking 255.255.255.0). With the "AXIS IP Utility", it is possible to determine the IP address under Windows; the included USB stick contains this application.

      https://www.axis.com/support/tools/axis-ip-utility

      If it is not possible to assign the IP address, it might be necessary to change the firewall settings! The "AXIS IP Utility" tool automatically recognizes all ExCam devices and visualises them in the device list. It can also be used to manually assign a static IP address. For this purpose, the ExCam IPP3827 network camera has to be installed in the same physical network segment (physical subnet) as the computer on which the AXIS IP Utility is running. The network signature of ExCam IPP3827 is "AXIS P3827". MAC address and serial number for clear device identification are also detected and displayed.

      To top

      Questions about our products

      If you have any questions about our products please contact our Sales Team.